Specification of

Model: DOC2-2 Description: AC Over Current Relay (0-2A) with 2 Contacts Utilization: The DOC2-2 monitors alternating current. Its setting is adjustable from zero to 2 .0a. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC2-2 is designed to sense over current. When the measured current is below the setting, two internal relays will energize and the green Up the LED comes ON while theRed Trip LED is OFF. If the current rises above the setting of the relays, the release and the green LED goes OFF while Up the red LED Trip comes ON. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC Frequency: 50 ~ 60 Hz Consumption: 2VA Voltage Circuit : 1VA Current Circuit On/TRIP Hysteresis: 2% of rated Adjustment: 0-2A Indication: Green LED (Up) Red LED (Trip) Dielectric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 5A 240V 50 Hz AC1 The Relay Up 11-14 Close 11-12 Open 21-24 Close 21-22 Open The Relay Trip 11-14 Open 11-12 pm Close 21-24 Open 21-22 Close

Model: 2D-DOC2 Description: AIR CONDITIONING Over Current Relay (0-2A) with Contacts and 2 Delay Utilization: The DOC2-2D monitors alternating current. Its current setting is adjustable from zero to 2A and the delay the setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC2-2D is designed to sense over current. When the measured current is below the setting, the two internal relays will energize and the green Up LED comes ON while the Amber Delay LED and the red LED'S are OFF the Trip. If the current rises above the Delay setting, the Amber LED comes ON; then after the set delay relays, the release and the green LED goes Up OFF while the red LED comes ON Trip. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC ❑ ❑ 12VDC 24VDC Frequency: 50 ~ 60 Hz Consumption:2VA Voltage Circuit : 1VA Current Circuit On/TRIP Hysteresis: 2% of rated Current Adjustment: 0-2A Delay Adjustment: 0-20 Sec Indication: Green LED (Up) Amber LEDS (Delay) Red LED (Trip) Dielectric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 2A 240V 50 Hz AC1 The relay Up Close 11-14 11-12 Open 2124-Close 21-22 Open The relay Trip 11-14 Open 11-12 pm Close 21-24 Open 21-22 Close

Model: DOC-5 Description: AC Over Current Relay (0-5A) Utilization: The DOC-5 monitors alternating current. Its setting is adjustable from zero to 5.0 a. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC-5 is designed to sense over current. When the circuit current is below the setting, an internal the relay will energise and Trip the red LED goes OFF while the green LED comes ON Up. If the current rises above the setting, the relay releases and the red LED comes ON the Trip while the green LED goes Up Off. Contacts 11-14 close Up in the condition and open in the Trip or No Supply condition. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC ❑ ❑ 12VDC 24VDC Frequency: 50 ~ 60 Hz Consumption: 2VA Voltage Circ.uit : 1VA Current Circuit On/TRIP Hysteresis: 2% of rated Current Adjustment: 0-5A Indication: Green LED (Up) Red LED (Trip) Dielectric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 5A 240V 50 Hz AC1 The relay Up Close 11-14, 11-12 Open The relay Trip 11-14, 11-12 Open-Close

Model: DOC-5 d Description: AIR CONDITIONING OverCurrent Relay (0-5A) with Delay Utilization: The DOC-5 d monitors alternating current. Its current setting is adjustable from zero to 5A and the delay the setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC-5 d is designed to sense over current. When the measured current is below the setting, an the internal relay will energize and the green LED comes ON Up while the Amber Delay LED and the red

Trip LED'S are OFF. If the current rises above the setting, the Amber Delay LED comes ON; then after the

set delay, the relay releases and the green LED goes OFF while Up the red LED comes ON Trip. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC ❑ ❑ 12VDC 24VDC Frequency: 50 ~ 60 Hz Consumption: 2VA Voltage Circuit : 1VA Current Circuit On/TRIP Hysteresis: 2% of rated Current Adjustment: 0-5A Delay Adjustment: 0-20 Sec Indication: Green LED (Up) Amber LEDS (Delay) Red LED (Trip) Dielectric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 5A 240V 50 Hz AC1 The relay Up Close 11-14, 11-12 Open The relay Trip 11-14, 11-12 Open-Close

Model: DOC2-5 Description: AC Over Current Relay (0-5A) with 2 Contacts Utilization: The DOC2-5 monitors alternating current. Its setting is adjustable from zero to 5.0 a. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC2-5 is designed to sense over current. When the circuit current is below the setting, two internal will energize relays and the red LED Trip goes OFF while the green LED comes ON Up. If the current rises above the setting of the relaysrelease and the red LED comes ON the Trip while the green LED goes Up Off. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC ❑ ❑ 12VDC 24VDC Frequency: 50 ~ 60 Hz Consumption: 2VA Voltage Circuit : 1VA Current Circuit On/TRIP Hysteresis: 2% of rated Adjustment: 0-5A Indication: Green LED (Up) Red LED (Trip) In Electric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 5A 240V 50 Hz AC1 The Relay Up 11-14 Close 11-12 Open 21-24 Close 21-22 Open The Relay Trip 11-14 Open 11-12 pm Close 21-24 Open 21-22 Close

Model: DOC2-5 d Description: AV Over Current Relay (0-5A), with the Contacts and 2 Delay Utilization:

/> The DOC2-5 d monitors alternating current. Its current setting is adjustable from zero to 5A and the delay setting is adjustable from 0 to 20 sec. The current circuit is connected to terminals S1 and S2 either directly or through current transformers. The DOC2-5 d is designed to sense over current. When the measured current is below the setting, the two internal relays will energize and the green Up the LED comes ON while the Amber Delay LED and the red LED'S are OF TripF. If the current rises above the Delay setting, the Amber LED comes ON; then after the set delay relays, the release and the green LED goes Up OFF while the red LED comes ON Trip. Contacts 11-14 & 21-24 close Up in the condition and open in the Trip or No Supply condition. Technical Data Supply Voltage: 240VAC ❑ ❑ 115VAC ❑ ❑ 12VDC 24VDC Frequency: 50 ~ 60 Hz Consumption: 2VA Voltage Circuit : 1VA Current Circuit ON/TRIPHysteresis: 2% of rated Current Adjustment: 0-5A Delay Adjustment: 0-20 Sec Indication: Green LED (Up) Amber LEDS (Delay) Red LED (Trip) Dielectric Strength Between: Current Voltage Circuit &: 3 kV Output Voltage Circuit &: 2 kV Output Contacts: 2 kV Output Contacts: 5A 240V 50 Hz AC1 The Relay Up 11-14 Close 11-12 Open 21-24 Close 21-22 Open The Relay Trip 11-14 Open 11-12 pm Close 21-24 Open 21-22 Close

Model: DUOC-5 Function: AC Over Current Relay & Under (0-5A). Utilization: The DUOC-5 monitors under and over alternating current source taken from; e. g a current transformer. It has two adjustable settings of zero to 5A for under and over current. It is only logical that the setting ' under ' be lower then the over ' setting '. The relay trips if the current of the monitored souRCE drops below or rises above the respective preset points. There are 2 separate sets of contacts; one for under current (11-14-12) and one for the over current (21-24-22). There are also 2 amber LEDs to indicate the normal condition. For under or over trip condition, the the corresponding LED will go off and the corresponding relay will de-energized. Technical Data Supply Voltage: 415V 2 ❑ Ph-2-Wire ❑ 240V 1-Ph, 2-Wire Frequency: 50 ~ 60 Hz Consumption: 2VA On Response Time: 200 msec. ROUND-TRIP Response Time: 200 msec. Hysteresis: 2% of rated Current Adjustment: 0-5A (under & over) CT Capacity: 1.5 VA Max Input Current: 15A. Indication: The Amber LED (Relay Up) Output Contacts: 5A 240V 50 Hz AC1 The Relay Up 11-14 Close 11-12 Open 21-24 Close 21-22 Open The Relay TRIP 11-14 Open 11-12 pm Close 21-24 Open 21

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot